image Use of an oversized, and worn, U-shaped insert in a wire stopper failed to restrain a pennant wire that came under tension, resulting in the death of an AB on an anchor handling tug, reports the International Maritime Contractors Association.

Says IMCA: “A member has reported a fatal incident which occurred during anchor handling operations. The incident occurred on an anchor handling tug (AHT) whilst crew were attempting to disconnect an anchor buoy weighing 1.4 tons from its pennant wire shortly after retrieval.

The anchor buoy was winched onto the deck of the AHT until the pennant was in the wire stopper used to prevent the buoy from being pulled back towards the stern by sudden tension on the pennant wire. (See Fig. 1 Step 1.)

image

Two crew members were disconnecting a shackle between the pennant wire connected to an anchor on the seabed and the buoy on deck (See Fig.1 Step 2), when suddenly the pennant wire came under tension.

image

The wire stopper failed to stop the pennant wire effectively and the sudden tension on the pennant wire jerked the buoy towards the stern of the vessel.

The two crew members who were busy disconnecting the shackle where struck by the moving buoy. (See Fig. 1 Step 3). One crew member died instantly, the other suffered a minor injury.

image

Root cause
Our member conducted an investigation and the root cause of the incident was determined to be that the wire stopper failed to stop the pennant wire. This happened because an incorrect (oversized with respect to the diameter of the pennant wire) ‘U-shaped insert’ was mounted into the wire stopper. This ‘U-shaped insert’ also displayed excessive wear and tear.

As a consequence of this the socket at the end of the pennant was able to pass through the wire stopper when the pennant wire came under tension.

The sudden tension on the pennant wire came about because the survey screen on the bridge of the AHT displayed a ‘design anchor position’ instead of the ‘as laid’ anchor position. Based on the information presented by the survey screen, it was
assumed that there was sailing slack in the pennant wire when in fact, it was being tensioned.

Recommendations and corrective actions
Our member made the following recommendations and corrective actions:

  • A thorough check of the wire stopper’s exchangeable parts should be made to ensure that it is adequate to handle the actual pennant wire diameter, and this should be recorded
  • A monthly inspection and check on wear and tear of the wire stopper equipment should be added to the vessel’s planned maintenance system
  • The ‘as laid’ information of the anchor should be provided by the positioning subcontractor and displayed on the survey screen
  • The survey screen provided by the positioning subcontractor should be considered an additional tool to provide an assumed anchor location to the AHT, but this location should never be interpreted as representing the actual anchor position. A warning message to this effect should be displayed on the survey screen
  • A dedicated watch should be maintained throughout the operation of buoy recovery on the direction and tension of the pennant wire.

Download further information here